Advance Catalyst Pvt Ltd
Advance Catalyst Pvt Ltd
Mumbai, Maharashtra
GST No. 27AAGCA3508A1Z9
TrustSEAL Verified
Call 08048941124 67% Response Rate
SEND EMAIL

Melt Flow Indexer

Our range of products include mfi-1312 melt flow indexer, mfi-1221 melt flow indexer, mfi-2322 melt flow indexer, mfi-1322 melt flow indexer, mfi-1211 melt flow indexer and mfi-3322 melt flow indexer.

MFI-1312 Melt Flow Indexer

MFI-1312 Melt Flow Indexer
  • MFI-1312 Melt Flow Indexer
Get Best Quote
Approx. Price: Rs 3.50 Lakh / PieceGet Latest Price

Product Details:

MaterialMS
Model Name/NumberMFI 1312
Voltage220 V
Temperature Range100 - 450
Type Of Testing MachinesMFI
ColorWhite
Usage/ApplicationFor Polymer Granules
Packaging TypeWooden Box
Display TypeTouchscreen
Load CapacityMotorized

It is an affordable tabletop instrument that tests the melt mass-flow rate (MFR) of a wide range of thermoplastic raw materials, in the form of granules, strips etc. The tester is far superior to all national and international standards of Melt Flow Rates requirements. This product has been CE certificated.

Features :

  • Touch screen control.
  • Fast heating rate, high temperature accuracy. With upper limit protection, sound notification functions.
  • Software has the functions of setting parameter, constant temperature control, cutting sample, calibration, setting test time as well as test result display.
  • Password verify is necessary for important operations in case of mishandle.
 
Request
Callback
Yes! I am Interested

MFI-1221 MELT FLOW INDEXER

MFI-1221 MELT FLOW INDEXER
  • MFI-1221 MELT FLOW INDEXER
Get Best Quote
Approx. Price: Rs 2.30 Lakh / PieceGet Latest Price

Product Details:

MaterialMS
Voltage220 V
Temperature Range100-450 C
Usage/ApplicationFor Polymer Granules
BrandFlexitest

It is an affordable tabletop instrument that tests the melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of a wide range of thermoplastic raw materials, in the form of granules, strips etc. The tester is far superior to all national and international standards of Melt Flow Rates requirements. This product has been CE certificated.

Features

  • LCD display the test result, l micro printer may print out the MVR result.
  • With the functions of test temperature display, upper limit protection and sound notification. Thanks to the advanced PID controller and high resolution sample circuit, the temperature can ramp up to the set point with slight overshoot and high accuracy in stability.
 
Request
Callback
Yes! I am Interested

MFI-2322 Melt Flow Indexer

MFI-2322 Melt Flow Indexer
  • MFI-2322 Melt Flow Indexer
Ask For Price
Product Price :Get Latest Price

Product Details:

MaterialMS
Model Name/NumberMFI-2322
Voltage220 V
Temperature Range100 to 450
Type Of Testing MachinesMFI
Usage/ApplicationFor Polymer Granules
ColorWhite
Packaging TypeWooden Box
Display TypeDigital
Load CapacityMotorized

 

It allows for the measurement of melt mass-flow rate (MFR) and melt volume-flow rate (MVR), melt density test according to the standards ASTM D1238, ISO1133(method A and B).

Features :

  • It allows for the measurement of melt mass-flow rate (MFR) and melt volume-flow rate (MVR), melt density test according to the standards ASTM D1238, ISO1133(method A and B).
  • 8"high resolution touch screen allows for fast & accurate input of test parameters and continuous display of settings during testing, printing the test result by a micro-printer.
  • With the additional function of loading the Weight automatically.
  • Can be connected to a PC through a RS232 port for direct acquisition of test parameters and results which can be directly saved or exported with the SW included in the supply.

 

Request
Callback
Yes! I am Interested

MFI-1322 Melt Flow Indexer

MFI-1322 Melt Flow Indexer
  • MFI-1322 Melt Flow Indexer
Ask For Price
Product Price :Get Latest Price

Product Details:

MaterialMS
Model Name/NumberMFI - 1322
Voltage220 V
Temperature Range100-450 C
Type Of Testing MachinesMFI
Usage/ApplicationFor Polymer Granules
ColorWhite
Packaging TypeWooden Box
Display TypeTouchscreen
Load CapacityMotorized

It is an affordable tabletop instrument that tests the melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of a wide range of thermoplastic raw materials, in the form of granules, strips etc. The tester is far superior to all national and international standards of Melt Flow Rates requirements. This product has been CE certificated.
Features :
  • MFR, MVR and melt density can be measured in one test.
  • Touch screen control, Chinese/English operating interface.
  • Fast heating rate, high temperature accuracy. With upper limit protection, sound notification functions.
  • Software has the functions of setting parameter, constant temperature control, cutting sample, calibration, setting test time, test result display, calculating melt density, as well as checking & printing test datum.
  • Password verify is necessary for important operations in case of mishandle.

 
Request
Callback
Yes! I am Interested

MFI-1211 MELT FLOW INDEXER

MFI-1211 MELT FLOW INDEXER
  • MFI-1211 MELT FLOW INDEXER
Ask For Price
Product Price :Get Latest Price

Product Details:

MaterialMS
Voltage220 V
Temperature Range100-450 C
Usage/ApplicationFor Polymer Granules
BrandFlexitest

It is an affordable tabletop instrument that tests the melt mass-flow rate (MFR) of a wide range of thermoplastic raw materials, in the form of granules, strips etc. The tester is far superior to all national and international standards of Melt Flow Rates requirements. This product has been CE certificated.

Features

  • LCD display the test result, micro printer may print out the MVR result. With the functions of test temperature display, upper limit protection and sound notification.
  • Thanks to the advanced PID controller and high resolution sample circuit, the temperature can ramp up to the set point with slight overshoot and high accuracy in stability.
 
Request
Callback
Yes! I am Interested

MFI-3322 MELT FLOW INDEXER

MFI-3322 MELT FLOW INDEXER
  • MFI-3322 MELT FLOW INDEXER
Ask For Price
Product Price :Get Latest Price

Product Details:

MaterialMS
Voltage220 V
Temperature Range50-450 C
Usage/ApplicationFor Polymer Granules
BrandFlexitest

The Melt Flow Indexer is related to the melted material viscosity. It allows the operator to make an estimation of " mean molecular weight", at the same time gives an indication of "melt flow ability" through a die.

The melt index is defined as the weight or the volume of melted material flowing through a calibrated die, under the effect of a pre-determined force, at constant temperature and for the total time of 10 minutes.

Features :

  1. Two-zone band heater
  2. Touch-screen control
  3. Quick die release
  4. Moveable oven for easy clean
  5. Cut the extrudate automatically at user preset intervals
  6. Powerful data analysis and control software
  7. CE Mark

Flow Rate Ratio (FRR)

Allow users to determine flow rate using two or three different test loads on one charge of material.

Motorized weigh loading

Motorized weight lifting and lowering device that further automates the testing procedure, desired weights are safely and automatically applied to the piston at a user selected time interval.

User friendly interface

Touch screen with simple set-up of test and operation. 
Connected to PC through RS232 for direct acquisition of test parameters and test results.

Multiple test results

  1. FFR
  2. Shear stress
  3. Shear rate
  4. Apparent density
  5. Diagram MVR vs Time
  6. Diagram MVR vs Time

Temperature

  • Temperature working range: 50oC to 450 oC
  • Temperature rising time: <30min
  • Temperature fluctuation: ± 0.5 oC
  • Temperature display error: ≤± 0.2 oC
  • Temperature recovery time: <4min
  • Accuracy of timer: 0.01s
  • Cut-off time interval: 1-36000s

Displacement

  • Encoder for piston displacement detection (MVR)
  • MVR measurement accuracy: ±0.03%F.S
  • Piston displacement accuracy: 0.02 mm
  • Piston displacement resolution: 0.005 mm

Weights

  • Automatic application of the selected weights
  • On board multi-weight system including following weights:0.325, 1.20,2.16, 3.80,5.00, 10.00, 21.60 kg
  • Accuracy of weight: ± 0.5%

Power supply

  • Power supply:(220-15% ∼220+10%) VAC 50Hz 800W

Dimension/weight

  • Dimension (L x W x H) :(630 x 690 x 1500) mm
  • Weight: About 180kg

 

Request
Callback
Yes! I am Interested

MFI-2322S Melt Flow Indexer

MFI-2322S Melt Flow Indexer
  • MFI-2322S Melt Flow Indexer
Ask For Price
Product Price :Get Latest Price

Product Details:

MaterialMS
Voltage220 V
Temperature Range50-450 C
Usage/ApplicationFor Polymer Granules

It allows for the measurement of melt mass-flow rate (MFR) and melt volume-flow rate (MVR), melt density test according to the standards ASTM D1238, ISO1133(method A and B).

Features:

  • It allows for the measurement of melt mass-flow rate (MFR) and melt volume-flow rate (MVR), melt density test according to the standards ASTM D1238, ISO1133(method A and B).
  • 8"high resolution touch screen allows for fast & accurate input of test parameters and continuous display of settings during testing, printing the test result by a micro-printer.
  • With the additional function of loading the Weight automatically.
  • Can be connected to a PC through a RS232 port for direct acquisition of test parameters and results which can be directly saved or exported with the SW included in the supply
 
Request
Callback
Yes! I am Interested
X

Explore More Product



Reach Us
Anuj Pirankar (Sales Coordinator)
Advance Catalyst Pvt Ltd
511, 5th Floor, Raikar Chamber, Govandi Station Road, Govandi East
Mumbai - 400088, Maharashtra, India


Call Us


Send E-mailSend SMS